Lenel LNL-1320-S3 Series 3 Dual Reader Interface Module with OSDP

The Lenel LNL-1320-S3 is the LenelS2 Series 3 Dual Reader Interface (DRI) module for OnGuard access control. It connects two card readers, keypads or readers with keypads to a LenelS2 Intelligent System Controller (ISC), with support for Wiegand, Magnetic Clock/Data, F2F and bidirectional RS-485 OSDP readers, including OSDP Secure Channel encryption and biometric template transfer. Each board adds 8 configurable inputs and 6 Form-C relay outputs, so door contacts, request-to-exit devices and lock strikes for two readers wire to one module. It is built for integrators expanding or upgrading OnGuard systems in commercial, education, healthcare and government buildings.

Key Specifications

SpecificationDetails
Reader ports2 readers: Wiegand Data 1/Data 0, Magnetic Clock/Data, supervised and unsupervised F2F, or OSDP (RS-485)
OSDP supportOSDP readers and keypads, including Secure Channel encryption and biometric template transfer
Inputs8 supervised/unsupervised (standard EOL 1k/1k ohm) + 2 dedicated (cabinet tamper, UPS fault)
Relay outputs6 Form-C: NO 5 A @ 30 Vdc, NC 3 A @ 30 Vdc
Card formatsUp to 16, with issue code support for magnetic and Wiegand formats
Host connectionRS-485 multidrop to the Intelligent System Controller (ISC): up to 32 modules, up to 4,000 ft per port
Communication securityAES 128-bit encryption to the ISC
Input power12 to 24 Vdc ±10%; 550 mA max @ 12 Vdc, 330 mA max @ 24 Vdc (plus reader current)
Reader power12 Vdc regulated or 12-24 Vdc pass-through, 300 mA max per reader
Operating temperature32°F to 158°F (0°C to +70°C), 5% to 95% RH non-condensing
ApprovalsUL 294, UL 2610, FCC Part 15, CE, RoHS
SoftwareLenelS2 OnGuard (current and previous versions, on-premise or OnGuard Cloud)

Full specifications are listed in the Detailed Specifications tab.

Why Choose the Lenel LNL-1320-S3?

  • Two reader ports on one board, each with door contact supervision, REX monitoring and strike control
  • OSDP support with Secure Channel encryption and biometric template transfer, alongside Wiegand, Clock/Data and F2F readers
  • 8 supervised or unsupervised inputs plus dedicated tamper and power failure circuits
  • 6 Form-C relay outputs that support fail-safe or fail-secure locking
  • Up to 32 modules multidropped on RS-485, up to 4,000 feet per port from the controller
  • AES 128-bit encrypted communication to the ISC
  • Lock, unlock and facility code offline modes keep doors working if the controller link drops
  • Compatible with current and previous versions of OnGuard, on-premise or OnGuard Cloud

OSDP and Multi-Technology Reader Support

The LNL-1320-S3 works with most access control card readers, keypads and readers with keypads that use standard Wiegand Data 1/Data 0 or Clock/Data communication, supervised and unsupervised F2F, and bidirectional RS-485 Open Supervised Device Protocol (OSDP). OSDP readers can use Secure Channel encryption and biometric template transfer, which makes the module a direct path for moving existing Wiegand doors to OSDP without changing controllers. Bicolor reader status LEDs, 2-wire LED control and beeper control are supported.

Door Inputs and Relay Outputs

Eight inputs support normally open, normally closed, supervised and unsupervised circuits (standard EOL 1k/1k ohm, 1%, 1/4 watt) for door contacts, REX push-buttons and other monitoring points. Two more unsupervised inputs are dedicated to cabinet tamper and UPS fault monitoring. Six Form-C relays, rated 5 A @ 30 Vdc normally open and 3 A @ 30 Vdc normally closed, drive door strikes and other devices in fail-safe or fail-secure mode.

Card Formats and Offline Operation

Each DRI supports up to 16 different card formats, plus issue codes for both magnetic and Wiegand formats. If communication with the ISC is interrupted, every reader on the module can run in lock, unlock or facility code offline access mode.

Cybersecurity and FIPS-201

Communication from the module to the ISC uses the Advanced Encryption Standard (AES) 128-bit algorithm, and OSDP Secure Channel encrypts the reader link. With an LNL-4420 or Lenel LNL-X4420 controller and the appropriate HID and OnGuard software and licenses, the module can connect FIPS-201 readers for embedded authentication.

Installation and Power

The module runs on 12 or 24 Vdc (±10%). An on-board regulator provides 12 Vdc reader power from a 24 Vdc source, or the input voltage can be passed through to the readers, at up to 300 mA per reader. DIP switches set the module address, on-board jumpers handle RS-485 termination, and firmware can be downloaded to the board. The board measures 6 x 8 x 1 in (152 x 203 x 25 mm) and weighs 11 oz (312 g).

Typical Applications

  • Adding two readers to an existing LenelS2 OnGuard controller
  • Upgrading Wiegand readers to encrypted OSDP readers
  • Entry and exit readers on secured doors that need door contact, REX and strike control
  • Government and federal sites using FIPS-201 credentials (with an LNL-4420 or LNL-X4420)
  • Schools, hospitals, corporate campuses and other multi-building OnGuard installations

Compatible Accessories

Compatible products for the Lenel LNL-1320-S3, available at Affinitech Store:

Intelligent System Controllers

Power Supplies and Batteries

OSDP Readers

Compare Lenel Series 3 Interface Modules

ModelCapacityTypeBest for
Lenel LNL-1300-S31 readerSingle Reader InterfaceAdding one reader to an OnGuard controller
Lenel LNL-1320-S3 (this module)2 readers, 8 inputs, 6 outputsDual Reader InterfaceTwo readers with door inputs and relays on one board
Lenel LNL-1100-S3Up to 16 inputsInput Control ModuleAlarm points, sensors and monitoring
Lenel LNL-1200-S3Up to 16 outputsOutput Control ModuleElevator floors, lighting and other relay control

Need one reader per board? See the Lenel LNL-1300-S3 Single Reader Interface Module.

Explore More

Frequently Asked Questions

What does the Lenel LNL-1320-S3 do?

The LNL-1320-S3 is a Series 3 Dual Reader Interface (DRI) module. It links up to two card readers, keypads or readers with keypads to a LenelS2 Intelligent System Controller (ISC) and adds 8 inputs and 6 relay outputs for door control in OnGuard.

Does the LNL-1320-S3 support OSDP readers?

Yes. It supports bidirectional RS-485 Open Supervised Device Protocol (OSDP) readers and keypads, including OSDP Secure Channel encryption and biometric template transfer.

Which reader types can I connect?

Readers and keypads using Wiegand Data 1/Data 0, Magnetic Clock/Data, supervised and unsupervised F2F, or OSDP over RS-485.

How many LNL-1320-S3 modules can connect to one controller?

Up to 32 DRI modules can be multidropped on RS-485 communication, up to 4,000 feet per port from the ISC. Total capacity depends on the ISC model, so check the controller's datasheet.

How many inputs and outputs does it have?

8 inputs that support normally open, normally closed, supervised and unsupervised circuits (standard EOL 1k/1k ohm), 2 dedicated inputs for cabinet tamper and UPS fault monitoring, and 6 Form-C relay outputs rated 5 A @ 30 Vdc normally open and 3 A @ 30 Vdc normally closed.

What power does the LNL-1320-S3 need?

12 to 24 Vdc ±10%: 550 mA maximum at 12 Vdc or 330 mA maximum at 24 Vdc, plus reader current. Readers get 12 Vdc regulated (jumper selectable, input of at least 20 Vdc) or the input voltage passed through, 300 mA maximum per reader.

Can I power 12 V readers from a 24 V supply?

Yes. The on-board regulator provides 12 Vdc reader power from a 24 Vdc power source.

What happens if communication with the controller is lost?

Lock, unlock and facility code offline access modes are supported on all readers connected to the DRI.

How many card formats does it support?

Up to 16 different card formats, with issue code support for magnetic and Wiegand formats.

Is communication to the controller encrypted?

Yes. The module uses the Advanced Encryption Standard (AES) 128-bit algorithm for communications to the ISC.

Does it support FIPS-201 readers?

Yes, with an LNL-4420 or LNL-X4420 controller and the appropriate HID and OnGuard software and licenses, the module can connect FIPS-201 readers for embedded authentication.

What certifications does the LNL-1320-S3 have?

FCC Part 15, CE, RoHS, UL 294 and UL 2610.

View AllClose

Detailed Specifications

Lenel LNL-1320-S3 Specifications

SpecificationDetails
Primary Power
Input voltage12 to 24 Vdc ±10%, 550 mA maximum (plus reader current)
Power consumption, 12 Vdc12 Vdc @ 550 mA (plus reader current) maximum, 22.5 BTUs
Power consumption, 24 Vdc24 Vdc @ 330 mA (plus reader current) maximum, 27.0 BTUs
Outputs
Relay outputs6 outputs, Form-C contacts
Normally Open (NO) contact rating5 A @ 30 Vdc
Normally Closed (NC) contact rating3 A @ 30 Vdc
Inputs
Configurable inputs8 unsupervised/supervised, standard EOL: 1k/1k ohm, 1%, 1/4 watt
Dedicated inputs2 unsupervised, dedicated for cabinet tamper and UPS fault monitoring
Reader Interface
Reader power, regulated12 Vdc ±10% regulated, 300 mA maximum each reader (jumper selectable; input voltage 20 Vdc minimum)
Reader power, pass-through12 to 24 Vdc ±10% (input voltage passed through), 300 mA maximum each reader
Reader port compatibilityWiegand Data 1/Data 0; Magnetic Clock/Data; Supervised and Unsupervised F2F; Open Supervised Device Protocol (OSDP)
OSDP featuresBiometric template transfer and Secure Channel encryption
Card formatsUp to 16 different formats; issue code support for magnetic and Wiegand formats
Door functionsDoor contact supervision (open/closed), REX push-button monitor, strike control output
Reader feedbackBicolor reader status LED support, 2-wire LED support, beeper control
Offline access modesLock, unlock and facility code
Communication
Host connectionRS-485 multidrop to the Intelligent System Controller (ISC)
Modules per ISCUp to 32 DRI modules (total ISC capacity varies by ISC model)
DistanceUp to 4,000 ft per port from the ISC
EncryptionAdvanced Encryption Standard (AES) 128-bit algorithm for communications to ISC
AddressingDIP switch-selectable
TerminationOn-board jumpers
FirmwareDownloadable
SoftwareCompatible with current and previous versions of OnGuard (on-premise or OnGuard Cloud)
FIPS-201Supported with LNL-4420 or LNL-X4420 and appropriate HID and OnGuard software and licenses
Mechanical
Dimensions6 in (152 mm) W x 8 in (203 mm) L x 1 in (25 mm) H
Weight11 oz (312 g) nominal
Environmental
Operating temperature32°F to 158°F (0°C to +70°C)
Storage temperature-67°F to 185°F (-55°C to +85°C)
Humidity5% to 95% RHNC
Compliance Approvals
ApprovalsFCC Part 15, CE, RoHS, UL 294, UL 2610